Lavatory Clearances

Figure 31
Lavatory Clearances

In addition to clearances discussed in the text, the following knee clearance is required underneath the lavatory: 27 inches (685 mm) minimum from the floor to the underside of the lavatory which extends 8 inches (205 mm) minimum measured from the front edge underneath the lavatory back towards the wall; if a minimum 9 inches (230 mm) of toe clearance is provided, a maximum of 6 inches (150 mm) of the 48 inches (1220 mm) of clear floor space required at the fixture may extend into the toe space. (4.19.2, 4.19.6)
 

 

Virginia Commonwealth University | www.dbtac.vcu.edu
National Institute on Disability and Rehabilitation Research (#H133A060087-01)
VCU DBTAC Coordination, Outreach and Research Center
1112 East Clay Street| P.O. Box 980330 | Richmond, Virginia 23298-0330
Phone: (804)827-0917 | Fax: (804) 828- 828-1321
This website is maintained by the VCU DBTAC Coordination, Outreach and Research Center.
The VCU DBTAC Coordination, Outreach and Research Center does not provide ADA technical assistance.
For ADA technical assistance, contact your local Center at 800-949-4232.
About this site.